CO alarms: warning, placement and response

Recognise what a CO alarm can establish, choose its position from the actual instructions, and put people first when it sounds.

A carbon monoxide alarm adds a warning layer. It does not maintain the appliance, test its flue or prove that required combustion air is available. A CO-only alarm also does not detect an escape of unburnt natural gas or LPG. Identify the device and its intended function before interpreting a signal or its absence.

Respond before troubleshooting

Treat a full CO warning as a potential exposure. Get everyone into fresh air and stop using the suspect appliance; only switch it off if safe. For a suspected gas-appliance incident in Great Britain, call 0800 111 999 from a safe location. Stay out until advised that returning is safe. Do not restart the boiler to see whether the alarm sounds again.

Possible CO symptoms need prompt medical advice. NHS 111 can advise on suspected poisoning; serious symptoms such as difficulty breathing, sudden confusion or loss of consciousness require 999. Do not ask an affected person to drive. Someone feeling better outdoors does not establish that the building is safe or that medical advice is unnecessary.

Decision check: everyone is outside, but one person is struggling to breathe. Request an ambulance immediately and explain the suspected exposure; do not wait for appliance diagnosis.

Place the sensor and the warning properly

Use the actual model instructions for the room, mounting position and surrounding airflow. Guidance can differ between a room containing a fuel-burning appliance and a bedroom without an appliance or passing flue. A remembered mounting height is not a universal rule.

Check what changed after decoration or furniture installation. A cabinet, curtain or extractor can make a previously suitable location unsuitable. Hearing the test sound through a cabinet does not establish that room air reaches the sensor correctly.

Audible warning is useful without visual inspection, but it does not guarantee that every sleeper will wake. Consider the layout and occupants' hearing needs when selecting the warning arrangement.

Test, maintain and replace the device

Follow the prescribed device checks and replacement date. What the test button checks depends on the model; some self-tests include the sensor as well as the power supply and horn. None is an inspection of the boiler's combustion or flue.

A CO warning, low-power indication, sensor fault and end-of-life indication may have different patterns. Read this model's instructions; do not assume every chirp means CO, or dismiss a reported full warning as a battery problem. Restoring protection and investigating a suspected exposure are separate jobs.

Decision check: the replace-by date has passed but the button test works. Replace the unit as instructed. A fresh battery or more frequent testing does not renew its specified service life.